TEST-RIG ENSURES HIGH PERFORMANCE STANDARDS |
| |
INTRODUCTION |
Today's building and construction industry has reached a level of sophistication that resulted in increasing concern for high performance in architectural aluminium systems. This development has led to the actual fabrication and installation work begin at the construction site. |
| |
| ACE Extrusion Sdn Bhd, in its continuing effort to promote and increase the usage of aluminium in the industry, has just the facility to provide architects and builders with the proven quality assurance. |
| |
AESB'S TEST RIG |
Built and calibrated by a certified inspection and testing laboratory in the United States of America in 1983, the RIG is designed to conduct test for air infiltration, water tightness and structural intergrity of the architectural systems. |
| |
|
AESB's Test Rig provides the opportunity for builders, architects and specitiers alike to witness the performance standards of their innovatively designed systems under simulated weather conditions. |
| |
|
|
|
THE TEST CHAMBER |
The Rig comprises a steel suction box or chamber measuring 9.10 m high x 4.60 m wide x 1.05 m deep. It is provided byt a 30 HP air blower capable of generating a static pressure of more than 1.0 m deep of water column at an air flow of 2600 cycles per minute. |
| |
|
The blower could be operated to generate positive and nefative static pressures respectively up to a maximum value of 7300 Pascal or 150lbs / sq.ft. either way |
| |
|
Test could be conducted in accordamce with either of the following testin procedures : |
| |
American Standards |
British Standard |
ASTM E283-73
Test for air leakage through exterior windows, curtain walls and doors. |
ASTM E330-79
Test for structural performance of exterior windows, curtain walls and doors by uniform static pressure differences. |
ASTM E331-70
Test for water penetration of exterior windows, curtain walls and doors by uniform static pressure differences |
|
BS 5368 Part 1 : 1976 EN 42
- Air permeability test |
BS 5368 Part 2 : 1980 EN 86
- Water tightness test under static pressure |
BS 5368 Part 3 : 1978 EN 77
- Wind resistance test |
|
|
| |
|
|
|